Black Box Async RS232 to RS422/485 Interface Converter - DB9 to Terminal Block

  • Part: 1012213
$199.49

Availability

In Stock

The BLACK BOX® Universal RS-232 to RS-422/485 Converter with Opto-Isolation isolates and converts RS-232 signals into RS-422/RS-485 signals and vice versa. Unlike other converters, external software is not required to control data flow. The RS-232 input is wired for DCE through a DB9 female connector, and RS-422/RS-485 signals are interfaced through a removable terminal block. To supply external power to the terminal block, you need our 120-VAC/12-VDC Wallmount Power Supply (PS1003).

For RS-232, the connection requires RD, TD, and Signal Ground.

In RS-422 mode, the driver is always enabled for full-duplex communications. A twisted pair is required for transmit, and a twisted pair is also required to receive. A ground reference wire is also needed. Switch settings are Switch 1: RS-422; Switch 2: Echo On; Switches 3 and 4: 4 Wire.

In both RS-485 modes, the RS-485 driver is automatically enabled during each space state by the presence of an RS-232 signal. When the RS-232 data is in a mark or idle state, the RS-485 driver is disabled and the RS-485 data lines are held in a mark state by the bias provided by a 4.7-ohm resistor; the value of this resistor may need to be changed, depending on the termination you use.

To connect to several RS-485 devices with minimal wire, select the unit's 2-wire, half-duplex RS-485 mode. When data is requested, the addressed device transmits and then reverts back to receive status. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo Off; Switches 3 and 4: 2 Wire.

For 4-wire master/slave circuits, select the unit's 4-wire, full-duplex RS-485 mode. In this mode, addressed devices can receive data while transmitting data from a previous request. When used as a master in a single-master system, Switch 1 may be selected because the unit is the only transmitter in the system. When used as an RS-485 slave, the RS-232 device must provide addressability. Biasing in a master/slave system is provided by the end-of-line slave. Switch settings for this mode are Switch 1: RS-485; Switch 2: Echo On; Switches 3 and 4: 4 Wire.

  • General Information
    • Manufacturer
    • Black Box Corporation
    • Manufacturer Website Address
    • http://www.blackbox.com
    • Brand Name
    • Black Box
    • Product Condition
    • New
    • Product Type
    • Transceiver/Media Converter
  • Warranty
    • Limited Warranty
    • 1 Year

  • Interfaces/Ports
    • Total Number of Ports
    • 2
  • Power Description
    • Power Source
    • Power Supply
    • Plug/Connector Type
    • Terminal Block
  • Physical Characteristics
    • Form Factor
    • External
    • Height
    • 1.7"
    • Width
    • 0.9"
    • Depth
    • 3.9"
  • Miscellaneous
    • Additional Information
    • Features:

      • Features 2000-VAC isolation
      • Selectable RS-422 operation
      • Select RS-485 for 2-wire half-duplex or 4-wire full-duplex
      • Auto RS-485 driver control.
    • Environmentally Friendly
    • Yes
    • Country of Origin
    • United States
    • TAA Compliant
    • Yes